GE Monogram Refrigerator Built In All Refrigerator Freezer User Manual |
Installation
Instructions
36" Built-In All-Refrigerators
and All-Freezers
31-46148
224D2601P001
06-08 JR
monogram.com
Design Guide
DIMENSIONS AND CLEARANCES
THE INSTALLATION SPACE
25-3/8" Framed Models
25-3/4" Stainless Steel Models
Case Depth
35"
Case Width
* Shipping height. The
The finished
cutout width
must be
product can be adjusted
to fit into a cutout that
is 83-1/2" min. to 84-1/2"
max. height. Note that
the top case trim
at the front is 1/2" higher
and will overlap upper
cabinetry or soffit. Use
leveling legs and wheels
for a maximum 1" height
adjustment.
35-1/2".
*84" From
Floor to
*83-1/2"
at
Top Frame
Rear
36" Frame to
Frame Width
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
Product Clearances
Water And Electrical Locations
These units are equipped with a 2-position door stop.
The factory set 130° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings between
90° and 130°.
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24" Minimum
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
130° Door Swing
90° Door Swing
25"
Minimum
to Wall
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 24" installation depth shown. The top case
trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply
is required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
130°
Note: GFI (ground fault interrupter) is not
recommended.
*4" stainless and trimmed models.
5" Pro models.
• Water line can enter the opening through the
floor or back wall. The water line should be 1/4" O.D.
copper tubing or GE QuickConnect™ kit between the
cold water line and water connection location, long
enough to extend to the front of the unit. Installation
of an easily accessible shut-off valve in the water line
is required.
Allow 25" minimum clearance for a full
130° door swing. Allow 15" for pan removal.
For a 90° door swing, allow 4" minimum clearance
to a wall for framed and stainless steel models.
Allow 5" minimum clearance for professional models.
If the 90° doorstop position is used, pan access
is maintained but pan removal is restricted.
See illustrations pages 5 and 6 to determine door swing
interaction with adjacent cabinets or countertops.
3
|